Description
Gas detection system KS-9000-N is a new type gas alarm controller of the latest design with simple operation. It can combine with our any kinds of gas detectors to form an industrial gas detection system. KS-9000-N used imported sensor and microcontroller, with high sensitivity, quick-response capacity and steady performance. When the concentration of the detecting gas reaches or exceeds the preset alarm point, the controller will alarm with acoustic and light signals to alert us to take measures. Synchronously, the actuator will start up to drive the exhauster or cut off valve and other peripheral equipments, in order to prevent poisoning accident, explosion and fire. So this system can guarantee regular production and the security of the lives and property.
The design of wall-mounting makes it convenient to choose the channels from 1 to 128 flexibly, namely every channel corresponds to a gas detector. Cooperating with the adaptive detector, KS-9000-N can inspect all kinds of gas, such as combustible gas, toxic gas, oxygen and so on. The probe output standard 4-20mA analog signal to the sampling circuit of the controller, the single chip of the controller uses drift compensation algorithm and intelligent algorithm for the signal, finally the system can successful to finish information display, output control, alarm history record and inquire, etc.
KS-9000-N is able to accomplish the real-time monitor and display status of the connected probe, alert with acoustic and light signals alarm status of the connected detector, synchronously keep the alarm record for all the channels, and the relay output control.
Field of applications include the industry of petroleum, gas, environmental protection, metallurgy, mining, energy, power, sewage treatment, water supply, paper making, printing and dyeing, chemical, pharmacy, etc.
Technical Specifications
Installation Means | Wall-mounting |
Input Signal | 8-N 4~20mA analog signal input; 80 channels of RS-485 digital signal in put |
Dimensions | 40*40*160cm |
Power Supply | 85~265V AC (50~60HZ) |
Reserve Power Supply | 12V DC rechargeable battery (optional) |
Operating Environment | Temperature: -20℃~45℃ Humidity: 10~90%RH (non-condensing) Atmospheric Pressure: 86~106Kpa |
Output Signal | 16 passive point (capacity: 2A/AC 220V) |
Display | Large LED display |
Alarm Signal | Built-in alarm withacoustic and light signals and failure-condition record |
Alarm Output | Electrical relay output (6 relays) |
Additional Function | Alarm silencing and alarm reset |
Power Consumption | ≤5 W / channel |